Plastech (Western) Ltd

Specialist Supplier of Drainage & Ducting Products

GLOUCESTERSHIRE OFFICE 01453 799860

  • Home Page
  • About Us
  • Our Product Range
  • Supplier Network
  • Contact Us
You are here: Home / Underground Drainage Systems / SFA8 Adoptable Inspection Chambers

SFA8 Adoptable Inspection Chambers

Complimenting the drainage systems which are available from Plastech (Western), both adoptable and non-adoptable inspection chambers & catchpits are available, which can take both EN1401 and Twin Wall pipes.

Category: Underground Drainage Systems Tag: inspection chambers
  • Description
  • Product Enquiry

Description

Complimenting the drainage systems which are available from Plastech (Western), both adoptable and non-adoptable access & inspection chambers & catchpits are available, which can take HS®, EN1401 and Twin Wall pipes.

These chambers offer versatility & flexibility as well as giving a significant overall saving on installation costs when compared to the traditional installations such as PCC chamber ring, preformed chambers and wet trades.

All of the chambers are classed as non-man entry access and limited to 3 metre inverts in adoptable installations, whilst in non-adoptable applications they are limited 6 metre depths. This is stipulated in Sewers for Adoption 8th Edition (Sfa8) and both the 450mm Ø & 600mm Ø range comply with SfA7 type 3 & 4 chamber specifications, which states that if the invert is above 1.2 metres then the access must be restricted to 350mm for safety compliance.

Manufactured from high strength polypropylene, the chambers are strong, extremely robust and can be installed in a minimum granular surround or suitable ‘as dug’ material. Whether you are installing a kit or single piece unit, the system offers a fully watertight chamber preventing the pollution of soils and ingress of water tables. They are also effective against aggressive soils and leachete from polluted land.

The options for the 450mm Ø & 600mm Ø bases are to have a straight 110mm channel, two 110mm inlets at 90° and two left/right 45° branch inlets or a mixed base, which have a straight 160mm channel, two 160mm inlets at 90° and two left/right 110mm 45° branch inlets. Standard chambers are available as either a complete single piece unit up to 2 meters deep or as a 3-part kit up to 6 metres that can be assembled on site.

Access & inspection chambers can be designed to be compatible with all UK Twin Wall pipe systems & specifically for surface water systems. They can however also be adapted to take structured wall drainage and other pipe systems. All ranges are designed for use in non-man entry access and inspection applications for inverts up to 3 metre in adoptable applications and 6 metres in non-adoptable applications, as stipulated in Sfa7.

The 600mm Ø range of inspection chambers with the option of a single straight half channel through the base and available with the option of either a 45° or 90° side inlet for secondary connections. Available in chamber depths of 1 and 2 metre in the single channel and 1 metre in the side inlet range.
600mm Ø inspection chambers can come with a 500mm deep catchpit for trapping silt and debris.

Product Enquiry

Loading

Related products

  • Twin Wall HDPE Surface Water Drainage System

    Read more
  • HS Pipe Sewer and Drainage System

    Funke HS® Adoptable Drainage System

    Read more
  • Cast Iron Drainage System

    Read more
  • Coiled Single Wall Land Drainage System

    Read more

Share This Page

Contact Us

Gloucestershire Branch | Tel: 01453 799860

Click here to submit an enquiry


Plastech (Western) Ltd.
Company No: 09626635
VAT Reg: 224088127

Website Terms & privacy | Copyright © Plastech (Western) Ltd. 2023

Cleantalk Pixel
Manage Cookie Consent
To provide the best experiences, we use technologies like cookies to store and/or access device information. Consenting to these technologies will allow us to process data such as browsing behaviour or unique IDs on this site. Not consenting or withdrawing consent, may adversely affect certain features and functions.
Functional Always active
The technical storage or access is strictly necessary for the legitimate purpose of enabling the use of a specific service explicitly requested by the subscriber or user, or for the sole purpose of carrying out the transmission of a communication over an electronic communications network.
Preferences
The technical storage or access is necessary for the legitimate purpose of storing preferences that are not requested by the subscriber or user.
Statistics
The technical storage or access that is used exclusively for statistical purposes. The technical storage or access that is used exclusively for anonymous statistical purposes. Without a subpoena, voluntary compliance on the part of your Internet Service Provider, or additional records from a third party, information stored or retrieved for this purpose alone cannot usually be used to identify you.
Marketing
The technical storage or access is required to create user profiles to send advertising, or to track the user on a website or across several websites for similar marketing purposes.
Manage options Manage services Manage {vendor_count} vendors Read more about these purposes
View preferences
{title} {title} {title}